PPC輕質載體填料在反硝化濾池中的應用研究
王偉燕1,2 王曉磊1,2 安少鋒1,3 押玉榮1,3
(1. 嘉誠環保工程有限公司,河北 石家莊050031;2.河北省污水治理與資源化技術創新中心,河北 石家莊050031;3.污水治理與水體修復工程研究中心,河北 石家莊050031)
摘 要:反硝化濾池是目前總氮去除的主要手段,本研究對比常規陶粒填料與PPC輕質載體填料在反硝化濾池中的應用效果,結果表明二者在填料掛膜階段并無明顯差異,在運行階段,PPC輕質載體填料更為穩定。
關鍵詞:反硝化濾池;PPC輕質載體填料;陶粒;掛膜
Study on the application of PPC light carrier filler in denitrification filter
WANG Xiaolei1,2, WANG Weiyan1,2, AN Shaofeng1,3,Ya yurong1,3
(1..Jiacheng Environmental Protection Engineering Co. Ltd.,Shijiazhuang 050031,China;2.Wastewater Treatment and Resource Reusing Technology Innovation Center of Hebei Province,Shijiazhuang 050031,China;3.Wastewater Treatment And Waterbody Remediation Engineering Research Center,Shijiazhuang 050031,China.)
Abstract:Denitrifying filter is the main method to remove total nitrogen at present. This study compared the application effect of conventional ceramsite packing and PPC light carrier packing in denitrifying filter. The results showed that there was no significant difference between them in the stage of biofilm formation, PPC lightweight carrier fillers are more stable during operation.
Key words:Denitrifying filter; PPC light carrier packing; ceramsite;Biofilm formation
前言
目前多數污水處理廠出水總氮要求達《城鎮污水處理廠污染物排放標準》(GB18918-2002)一級A標準,隨著污水廠水質提標改造進行,要求污水處理廠水質達到準三類或者準四類要求,關于總氮北京、天津等執行地方標準,河北也出了相應的流域標準,對污水處理廠總氮排放提出了更高要求。針對該種情況,對污水處理廠總氮深度處理技術開發和使用成為必然。
經過生化二級處理后二沉池出水總氮濃度一般為15-30mg/L[1],此時總氮主要為硝態氮,因此一般采用反硝化生物濾池技術進行脫氮[2]。常用的反硝化載體填料為陶粒或者海砂,一般運行水頭損失為1.5-2m,反洗頻率為2天1次(實際運行一天1次),運行水頭損失較大,反洗頻率高,耗能較多。圍繞水廠節能降耗的目的和新技術開發需求,本項目預采用新型PPC載體作為反硝化載體,以提高掛摸效果與脫氮效率,降低反硝化運行水頭損失。
本試驗采用兩組對比試驗,其中一組以陶粒為濾料載體,另外一組以PPC輕質載體為濾料,對比獲得PPC輕質載體與陶粒在反硝化濾池中掛膜情況和運行情況,以判斷PPC輕質載體作為濾池填料的可行性。
-
12:35已群發
-
昨天 12:01已群發
-
星期一 10:56已群發
-
星期日 12:05已群發
-
星期六 00:00已群發
-
星期五 00:00已群發
-
07月22日已群發